Hioki PW3365 Clamp on Power Logger is a high-precision power measurement device designed for accurate energy monitoring in industrial and commercial applications. Its clamp-on design allows effortless measurement of AC/DC current without disconnecting circuits, making it ideal for real-time monitoring and analysis of electrical systems. The PW3365 supports multi-channel logging, enabling simultaneous recording of voltage, current, power, and energy data. With intuitive display and robust data storage, it ensures detailed power analysis for energy audits, troubleshooting, and preventive maintenance.
Engineered for professionals, the Hioki PW3365 Clamp on Power Logger offers advanced safety features, compact portability, and seamless connectivity to data management software. It is perfect for engineers, facility managers, and energy consultants looking to optimize energy usage and reduce operational costs.
For those searching for Hioki PW3365 Clamp on Power Logger Price in Bangladesh, this device represents a reliable investment in precision and durability, backed by professional support and service. Its efficiency in capturing accurate electrical measurements positions it as an essential tool in Power & Energy monitoring projects.
Pico Labs Ltd. provides expert calibration, rental, and technical support for all Hioki instruments, ensuring that your devices operate at peak performance. Our dedicated team in Bangladesh delivers professional solutions tailored for industrial, commercial, and research applications.
Delivering reliable calibration and rental services, Pico Labs Ltd. ensures top performance for all electrical test and measurement instruments. Trusted by industries across Bangladesh, we offer expert support, precision testing, and tailored solutions for energy, electrical, and industrial monitoring projects, helping businesses maintain efficiency and compliance.
Accuracy guaranteed: 1 year
| Measurement line & number of circuits | 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels | |||||
|---|---|---|---|---|---|---|
| Measurement items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand | |||||
| Voltage ranges | 400 V AC (Effective measurement range: 90.0 V to 520.0 V) | |||||
| Harmonic | Harmonic voltage, harmonic current, voltage total harmonic distortion (THD-F or THD-R), current total harmonic distortion (THD-F or TDH-R), up to 13th order | |||||
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) |
|||||
| Power ranges | 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type) | |||||
| Basic accuracy | Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020) Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1) |
|||||
| Display update rate | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) | |||||
| Save destination | SD/SDHC Memory card, or internal memory at real time | |||||
| Data save interval | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections | |||||
| Save items | Measurement value save: Average only / Average, Maximum, Minimum value Screen copy: BMP form (saved every 5 min. at minimum interval time) Waveform save: Binary waveform data |
|||||
| Interfaces | SD/SDHC memory card, LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download, USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download | |||||
| Functions | Connection check, Quick Set navigation guide, clock | |||||
| Power supply | AC adapter Z1008: (100 to 240 V AC, 50 Hz/60 Hz), 45 VA (including AC adapter) Battery pack 9459: (Max. rated power 5 VA, charging time 6 hr 10 m), 3 hours of continuous use (with backlight off) |
|||||
| Dimensions and mass | 180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002 180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002 |
|||||
| Included accessories | Safety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip (red, yellow, blue and white each 4), Spiral tubes in black (cord bundling for current sensors and voltage sensors) ×10 | |||||
| Compatible conductor types | Insulated wires* In door PVC or metal parts *Shielded wires cannot be measured. The product may not be able to accurately measure multi-core cables or cables that have thick insulation. |
|---|---|
| Compatible conductor diameters | Finished outer diameter φ6mm to φ30mm |
| Effective measurement range | 90 V rms to 520 V rms |
| Cord length | 3m (9.84 ft) |