Get Support

123-456-789-10

Fluke RaySafe i3 Real-time Dose Monitoring System

  • Home
  • Fluke RaySafe i3 Real-time Dose Monitoring System

Fluke RaySafe i3 Real-time Dose Monitoring System in Bangladesh

In modern hospitals, especially in cath labs, interventional radiology, cardiology, and operating theatres, medical staff are frequently exposed to ionizing radiation. Protecting doctors, nurses, and technicians from unnecessary radiation is a critical safety priority.

The Fluke RaySafe i3 Real-time Dose Monitoring System is designed to provide instant, continuous radiation dose feedback to staff, helping them optimize their working habits and reduce exposure. In Bangladesh, this system is an excellent solution for hospitals looking to implement international radiation safety standards and build a culture of protection in imaging-intensive departments.

Pico Labs Limited is a reliable technology provider in Bangladesh where you can explore a wide range of Biomedical Test Equipment at the best price. From hospitals and clinics to diagnostic centers and biomedical engineering departments, you can find professional analyzers, simulators, and test tools for accurate performance checking of medical devices like infusion pumps, defibrillators, patient monitors, incubators, and ventilators.

Why Real-Time Dose Monitoring Matters in Bangladesh

Traditional passive dosimeters (TLD/film badges) show cumulative exposure after weeks or months, but cannot help staff adjust behavior during procedures. The RaySafe i3 solves this by providing instant feedback, allowing staff to:

  • Step back when dose rates are high
  • Use shielding more effectively
  • Adjust C-arm angulation and fluoroscopy time

This is particularly important in Bangladesh where busy hospitals and high patient loads can lead to frequent fluoroscopy use and increased cumulative exposure for staff.

Benefits of Fluke RaySafe i3 for Hospitals in Bangladesh

1. Improved Staff Safety
Real-time information motivates staff to adopt safer working practices, directly reducing personal dose over time.

2. Supports Radiation Protection Policies
Helps hospitals implement ALARA (As Low As Reasonably Achievable) principles and comply with radiation safety protocols.

3. Educational Tool for Staff
The live display acts as a training tool – when staff see dose jump after certain actions, they learn how to work more safely.

4. Better Documentation & Reporting
Dose history can be used for internal audits, safety meetings, and compliance documentation.

5. Positive Safety Culture
Visible monitoring fosters a safety-focused environment, improving staff confidence and satisfaction.

System Overview and Typical Specifications

Component Description
Personal Dosimeter Wearable badge for individual staff dose tracking
Real-Time Display Unit Wall or cart-mounted monitor showing live doses
Measured Quantity Accumulated dose and dose rate
Number of Users Multiple dosimeters can be tracked simultaneously
Communication Wireless connection between dosimeters and display
Data Storage Dose history stored for later review
Environment Designed for cath labs, IR suites, ORs
Power Mains power for display, battery for dosimeters

(Exact values and ranges vary by configuration and should be verified from the product datasheet at purchase time.)

Applications of RaySafe i3 in Bangladesh

  • Cath Labs (Cardiology & Interventional Radiology)
    Continuous monitoring during angiography, stenting, EP studies, and complex interventions.

  • Hybrid Operating Rooms
    Spine surgery, vascular surgery, and image-guided procedures with fluoroscopy.

  • Interventional Radiology Suites
    Embolization, biopsies, and other fluoroscopy-guided procedures.

  • Radiation Safety Programs
    Used by hospital radiation safety officers for monitoring and optimizing staff exposure.

  • Training Hospitals and Institutes
    Teaching residents and fellows how to work safely around X-ray sources.

Implementation Considerations in Bangladesh

When planning to deploy the Fluke RaySafe i3 Real-time Dose Monitoring System in a Bangladeshi hospital, consider:

  • Number of Staff per Lab
    Determine how many dosimeters are needed for doctors, scrub nurses, anesthetists, and technicians.

  • Location of Displays
    Place displays where staff can easily see them during procedures (e.g., near control panels or on wall mounts).

  • Integration with Safety Protocols
    Combine RaySafe i3 with existing lead aprons, shields, and training programs for maximum benefit.

  • Data Management
    Set a schedule for reviewing dose reports (monthly/quarterly) and using data for safety improvement.

  • Training & Orientation
    Provide short training sessions so users understand how to interpret the display and adjust behavior.

Advantages for Management and Administration

Hospital management in Bangladesh benefits from RaySafe i3 in several ways:

  • Proof of Safety Initiatives – Demonstrates commitment to staff safety and modern radiation protection.
  • Reduced Long-Term Risk – Lower staff dose may reduce long-term occupational health issues.
  • Better Compliance for Accreditation – Supports national and international accreditation standards that require radiation safety measures.

The Fluke RaySafe i3 Real-time Dose Monitoring System in Bangladesh is an advanced solution for protecting healthcare professionals who work daily with fluoroscopy and X-ray–based procedures. By providing instant, easy-to-understand feedback on radiation exposure, it helps staff change their working habits, reduces unnecessary dose, and strengthens overall radiation safety culture.

For hospitals, cath labs, and interventional centers in Bangladesh, investing in RaySafe i3 means investing in safer workplaces, better compliance, and long-term protection of valuable medical teams.

Key Features: Fluke RaySafe i3 Real-time Dose Monitoring System

The RaySafe i3 system consists of personal dosimeters and a real-time display unit, working together to provide live dose information:

  • Real-Time Dose Monitoring – Displays radiation dose rate and accumulated dose instantly while procedures are ongoing.
  • Wearable Personal Dosimeters – Lightweight badges worn by staff over the lead apron.
  • Live Visual Feedback – Screen display shows each user’s dose, helping them adjust distance, shielding, and positioning.
  • Multiple User Support – Can monitor several staff members simultaneously in the same room.
  • Data Logging and Analysis – Stores dose histories for review, reporting, and long-term optimization.
  • Simple Integration – Easy to install in cath labs, hybrid ORs, and interventional suites.
  • Durable and Reliable – Designed for daily use in demanding clinical environments.

Specifications: RaySafe i3 Real-time Dose Monitoring System

Dosimeter

Weight

34 g (1.20 ounces)

Dimensions

40x58 x17 mm (1.6 x2.3 x 0.7 inch)

Operational quantity

H p (10)

Energy Dependence

<25% (N-series, 40 - 150kV)

Temperature Dependence

  • <5%(18 °C 26 °C)
  • <25% (15 °C to 18 °C, 26 °C to 35 °C)

Response Time

  • <1 s, above 100 Sv/h
  • <5 s, below 100 Sv/h

Integration Interval

1 s

Detection Limit

<30Sv/h

Dose Rate Uncertainty
(continuous radiation)

  • 10% or 10Sv/h (40 Sv/h 150 mSv/h)
  • 20% (150 mSv/h 300 mSv/h)
  • 40% (300 mSv/h 500 mSv/h)
  • The measured dose rate is monotonically increasing up to 1 Sv/h.

Dose Reproducibility

10% or 1 Sv

Maximum Lifetime Dose

10 Sv

Battery

°CR2450 (replaceable, 1 2 years lifetime depending on usage)

°Communication

Radio communication to real-time display, carrier frequency depending on region. USB port for connection to PC

Real-time display

Dose unit

Sv or rem

Dimensions

300 x 250 x 60 mm (11.8 x 9.8 x 2.4 inch)

Weight

1240 g (43.74 oz)

Display

10.4" touch screen

Storage

Dose rate by second and accumulated dose by hour for connected dosimeters. For 50 dosimeters the memory size allows storage of up to 5 years of accumulated dose and dose rate for the last 250 hours of exposure each.

Interfaces

Ethernet connection for Dose Manager USB connection for synchronizing data to USB memory stick

Power

12 V DC, <1.5 A External power supply included

Software Requirements

Operating System

Windows XP, Vista, 7, 8 or 10

System Memory

  • At least 1 GB (Dose Viewer)
  • At least 2 GB (Dose Manager)

USB °Connection

1 USB 2.0

Hard Drive

At least 15 GB available space (Dose Manager)

 

Instrument specifications are subject to purchased configuration. All specifications may change without notice.
Product is not available in every country. °Check with your local representative for further information.

Customer Reviews


Add a Review

Your Ratings: