Get Support

+8801977426642

Fluke ESA609 Electrical Safety Analyzer

  • Home
  • Fluke ESA609 Electrical Safety Analyzer

Fluke ESA609 Electrical Safety Analyzer in Bangladesh

The Fluke ESA609 Electrical Safety Analyzer is an entry-level, reliable device designed to perform essential electrical safety tests on medical equipment. In Bangladesh, it is suitable for hospitals, clinics, diagnostic centers, biomedical engineering departments, and service providers that need a cost-effective solution for routine safety verification of medical devices. Pico Labs Limited is a reliable technology provider in Bangladesh where you can explore a wide range of Biomedical Test Equipment at the best price. From hospitals and clinics to diagnostic centers and biomedical engineering departments, you can find professional analyzers, simulators, and test tools for accurate performance checking of medical devices like infusion pumps, defibrillators, patient monitors, incubators, and ventilators.

The ESA609 helps ensure that medical equipment is electrically safe for patients and staff, supporting both compliance with safety standards and the prevention of electrical hazards in healthcare facilities.

Key Features of Fluke ESA609 Electrical Safety Analyzer

The ESA609 provides core electrical safety functions with simplicity and portability. Typical features include:

  • Essential electrical safety tests for medical devices
  • Ground (earth) resistance measurement to verify protective earth continuity
  • Equipment leakage current testing for enclosure and mains leakage
  • Simple and intuitive controls for ease of operation
  • Digital display for clear reading of measurements
  • Portable and durable design suitable for field or workshop use
  • Optimized for routine checks and basic preventive maintenance

These features make it a practical choice for facilities that want to ensure electrical safety without the complexity of high-end analyzers.

Example Technical Overview Table

The table below provides a simplified overview of typical functions and characteristics of an electrical safety analyzer like the Fluke ESA609. Actual specifications may vary depending on configuration.

Parameter / Function Typical Description
Ground Wire Resistance Measures continuity of protective earth conductor
Equipment Leakage Current Measures leakage from enclosure and mains components
Test Modes Manual selection for standard medical devices
Display Digital numeric readout
Test Sequences Preset basic sequences for routine checks
Power Source Mains-powered
Portability Compact, suitable for field and bench use
Operation Simple buttons and menu navigation
Application Environment Hospitals, clinics, labs, service centers
Typical Use Routine electrical safety verification of medical devices

This table is for general understanding and not a formal datasheet.

Applications of ESA609 in Bangladesh

The Fluke ESA609 Electrical Safety Analyzer is widely applicable in the Bangladeshi healthcare and biomedical sector:

  • Hospitals and Clinics
    Used to perform basic electrical safety checks on patient monitors, infusion pumps, ventilators, anesthesia machines, and other electrically powered devices.

  • Diagnostic Centers
    Ensures electrical safety compliance for devices in imaging, laboratory, and procedural areas.

  • Service and Maintenance Providers
    A portable and simple solution for on-site electrical safety testing at multiple facilities.

  • Medical Equipment Workshops
    Supports pre-delivery inspections, post-repair testing, and preventive maintenance programs.

By regularly testing equipment with the ESA609, organizations reduce the risk of electrical hazards and improve overall patient and staff safety.

Benefits for Hospitals and Biomedical Teams

Using the Fluke ESA609 provides several advantages:

  1. Improved Safety
    Routine checks of ground continuity and leakage currents help prevent electric shock incidents.

  2. Ease of Use
    Simple controls and a clear digital display make testing quick and efficient, even for less experienced technicians.

  3. Standardized Basic Testing
    Using a dedicated analyzer allows biomedical teams to implement consistent safety testing procedures.

  4. Cost-Effective Solution
    Provides essential electrical safety functions without the higher costs associated with advanced analyzers.

  5. Support for Preventive Maintenance
    Integrating ESA609 testing into maintenance schedules enables early detection of issues, reducing equipment downtime and unexpected failures.

Typical Test Workflow with ESA609

A common workflow for using the ESA609 in Bangladeshi healthcare facilities:

  • Visual Inspection – Check the device’s cables, plugs, and casing for damage.
  • Ground Resistance Test – Verify protective earth continuity.
  • Equipment Leakage Current Test – Ensure leakage from mains and enclosures is within safe limits.
  • Result Evaluation – Compare measured values with internal safety limits to determine pass/fail.
  • Documentation – Record results in maintenance logs for compliance and audits.

This workflow ensures safe, repeatable, and documented testing for all electrical medical devices.

Considerations Before Using or Purchasing in Bangladesh

Before purchasing or using the Fluke ESA609 Electrical Safety Analyzer, consider the following:

  • Compatibility with Device Types
    Ensure the analyzer supports the types of medical equipment in your facility (e.g., Class I, Class II, BF, CF).

  • User Training
    Provide basic training on proper connections, electrical safety, and result interpretation.

  • Calibration and Accuracy
    Plan for periodic calibration to maintain confidence in test results.

  • Integration into Maintenance Plans
    Include ESA609 testing as part of installation, preventive maintenance, and post-repair checks.

  • Documentation Practices
    Maintain proper logs of test results for internal audits, quality assurance, and regulatory compliance.

The Fluke ESA609 Electrical Safety Analyzer is an entry-level, practical tool for ensuring the electrical safety of medical equipment in Bangladesh. Its simple operation, portability, and focus on essential safety functions make it ideal for hospitals, clinics, diagnostic centers, and service workshops.

Key Features: Fluke ESA609 Electrical Safety Analyzer

  • IEC Standards compliance: ANSI/AAMI ES1, NFPA-99, and parts of IEC62353 and IEC60601-1
  • Portable: Featherweight design, functional strap, and tilt stand make it easy for transportation and operation on-the-go (onsite or offsite)
  • User-friendly: Quick push-button operation for rapid testing
  • Rugged: Rubberized case and Ingress Protection rating of IP30 help prevent damage when dropped
  • Global use: the ESA609 will operate at 120V and 230V
  • Test current consumption up to 20A for a diverse set of medical devices
  • All parameters needed for basic electrical safety testing: Line (Mains) voltage, Ground Wire (or Protective Earth) Resistance, Equipment current, Ground Wire (Earth) leakage, Chassis (Enclosure) leakage, Direct equipment leakage, and Point to point leakage and resistance
  • Rigorously tested for safety and reliability, with CE, CSA and Australia RCM in addition to Fluke quality
  • Two-year extended warranty (no-cost, available after first-year calibration at any authorized Fluke Biomedical Service Center)
  • Global support network delivering prompt service and peace of mind to Fluke Biomedical customers worldwide

Specifications: Fluke ESA609 Electrical Safety Analyzer

Specifications

 

Display: LCD display
Modes of Operation: Manual
General: Answer

Temperature

 

Storage: -20 °C to 60 °C (-4 °F to 140 °F)
Humidity: 10 % to 90 % non-condensing

Altitude

 

120 V ac mains supply voltage: 5000 m
230 V ac mains supply voltage: 2000 m

Power Ratings

 

115 Volt power outlet: 90 to 132 V ac rms, 47 to 63 Hz, 20 A maximum
230 Volt power outlet: 180 to 264 V ac rms, 47 to 63 Hz, 16 A maximum
Power input: 115V 20A – 2.6kVA and 230V at 16A – 4.2kVA

Physical case

 

Weight: 0.7 kg (1.5 lb)
Dimensions (WxDxH): 22.9 cm x 17.8 cm x 6.4 cm (9 in x 7 in x 2.5 in)

Environmental

 

Agency Approvals: CE, CSA, Australia RCM
Safety: IEC 61010-1:Overvoltage Category II, Measurement 300V CAT II, Pollution Degree 2
Electromagnetic Environment: IEC 61326-1:Portable
Safety: IEC CISPR 11:Group 1, Class A.

 

  • Group 1 have intentionally generated and/or use conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.
  • Class A equipment is suitable for use in nondomestic locations and/or directly connected to a low-voltage power supply network

Customer Reviews