Phototherapy is a common treatment for neonatal jaundice, and the effectiveness of therapy depends on the intensity of the light delivered to the infant. The Fluke DALE40 Phototherapy Radiometer is a precision device designed to measure the irradiance of phototherapy lights accurately. Hospitals and neonatal care units in Bangladesh can rely on the DALE40 to ensure optimal treatment, patient safety, and compliance with medical standards.
Pico Labs Limited is a reliable technology provider in Bangladesh where you can explore a wide range of Biomedical Test Equipment at the best price. From hospitals and clinics to diagnostic centers and biomedical engineering departments, you can find professional analyzers, simulators, and test tools for accurate performance checking of medical devices like infusion pumps, defibrillators, patient monitors, incubators, and ventilators.
1. Ensures Effective Treatment
Accurate measurement of light intensity guarantees that infants receive the correct dosage of phototherapy.
2. Enhances Patient Safety
Prevents under- or over-exposure to phototherapy light, reducing risks to neonatal patients.
3. Compliance with Standards
Supports hospital quality control and adherence to medical device guidelines.
4. Cost-Effective Solution
Portable and reliable, minimizing the need for repeated measurements or expensive equipment calibration.
5. Easy to Use
Simple operation allows healthcare staff to quickly check light levels without specialized training.
| Parameter | Specification |
|---|---|
| Measurement Type | Phototherapy irradiance (μW/cm²/nm) |
| Measurement Range | 0 – 100,000 μW/cm²/nm |
| Light Sources Supported | LED, fluorescent, and conventional phototherapy lamps |
| Accuracy | ±5% of reading |
| Display | Digital LCD for easy reading |
| Power Supply | Rechargeable battery / AC adapter |
| Dimensions | 180 × 100 × 50 mm |
| Weight | 0.5 kg |
| Portability | Handheld and lightweight |
The Fluke DALE40 Phototherapy Radiometer is an essential tool for hospitals and neonatal care units in Bangladesh. It ensures accurate measurement of phototherapy light intensity, supports effective treatment of neonatal jaundice, and enhances patient safety. Its portability, precision, and ease of use make it a reliable and practical solution for healthcare professionals.
The DALE40 offers advanced functionalities for accurate phototherapy light measurement:
| Specification | Details |
|---|---|
| Measurement Range | 0 to 2999 µW/cm²/nm |
| Spectral Range | 400 – 520 nm (Blue light) |
| Detector Type | Silicon photodiode with optical filter |
| Display | 3½ digit LCD |
| Resolution | 1 µW/cm²/nm |
| Accuracy | ±5% of reading ±1 digit |
| Calibration | NIST traceable calibration |
| Power Supply | 9V battery (alkaline) |
| Battery Life | Approximately 100 hours continuous use |
| Auto Power-Off | Yes (for battery preservation) |
| Operating Temperature | 10°C to 40°C (50°F to 104°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Dimensions | 7.5 in × 3.5 in × 1.5 in (190 mm × 89 mm × 38 mm) |
| Weight | Approximately 0.5 lbs (230 g) |