EXTECH HD350 Pitot Tube Anemometer Plus Differential Manometer is a precision instrument designed for accurate airflow and differential pressure measurements in HVAC systems, clean rooms, and industrial environments. With its high-resolution pitot tube anemometer, it delivers reliable airflow velocity readings, while the integrated differential manometer provides precise pressure measurements across ducts, filters, and cleanroom environments. The HD350 features user-friendly controls, a large digital display, and robust data logging capabilities, making it ideal for engineers and technicians conducting airflow analysis, system balancing, and environmental monitoring. Lightweight and portable, it ensures easy transport between work sites, while its durable construction withstands demanding field conditions.
Engineered for versatility, this anemometer supports multiple units of measurement and offers real-time readings for both velocity and pressure, helping optimize HVAC performance and maintain strict cleanroom standards. Trusted by professionals for its accuracy and reliability, the EXTECH HD350 is essential for inspections, commissioning, and preventive maintenance tasks.
Optimize your workflow with confidence, knowing you have a dependable instrument that combines airflow measurement and differential pressure monitoring in a single, easy-to-use device.
EXTECH HD350 Pitot Tube Anemometer Plus Differential Manometer Price in Bangladesh makes this advanced technology accessible to local professionals and businesses, ensuring high-quality results for every HVAC and cleanroom application.
Pico Labs Ltd. offers reliable calibration and rental services for electrical test measurement instruments across Bangladesh. Our expert team ensures accuracy, timely delivery, and professional support, helping businesses maintain optimal performance and compliance. Trust Pico Labs Ltd. for precision, reliability, and unmatched customer service in the testing and calibration industry.
| Temperature - NTC | |
|---|---|
|
Measuring range |
-20 to +50 °C |
|
Accuracy |
±0.2 °C (-10 to +50 °C) |
|
Resolution |
0.1 °C (-20 to +50 °C) |
Ambient temperature probe
| Temperature - TC Type K (NiCr-Ni) | |
|---|---|
|
Measuring range |
-200 to +1370 °C |
|
Accuracy |
±0.4 °C (-100 to +200 °C) ±1 °C (-200 to -100.1 °C) ±1 °C (200.1 to +1370 °C) |
|
Resolution |
0.1 °C (-200 to +1370 °C) |
| Temperature - TC Type S (Pt10Rh-Pt) | |
|---|---|
|
Measuring range |
0 to +1760 °C |
|
Accuracy |
±1 °C (0 to +1760 °C) |
|
Resolution |
0.1 °C (0 to +1760 °C) |
| Differential Pressure - Piezoresistive | |
|---|---|
|
Measuring range |
-40 to +40 hPa -200 to +200 hPa |
|
Accuracy |
±1.5 % of mv (-40 to -3 hPa) ±1.5 % of mv (+3 to +40 hPa) ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (-200 to -50 hPa) ±1.5 % of mv (+50 to +200 hPa) ±0.5 hPa (-49.9 to +49.9 hPa) |
|
Resolution |
0.01 hPa (-40 to +40 hPa) 0.1 hPa (-200 to +200 hPa) |
| Absolute Pressure | |
|---|---|
|
Measuring range |
600 to +1150 hPa |
|
Accuracy |
±10 hPa |
|
Resolution |
1 hPa |
| Flue gas O₂ | |
|---|---|
|
Measuring range |
0 to +25 Vol.% |
|
Accuracy |
±0.8% of fsv (0 to +25 Vol.%) |
|
Resolution |
0.01 Vol.% (0 to +25 Vol.%) |
|
Reaction time t₉₀ |
20 s (t₉₅) |
| Flue gas CO (with H₂-compensation) | |
|---|---|
|
Measuring range |
0 to +10000 ppm |
|
Accuracy |
±5 % of mv (+200 to +2000 ppm) ±10 % of mv (+2001 to +10000 ppm) ±10 ppm (0 to +199 ppm) |
|
Resolution |
1 ppm (0 to +10000 ppm) |
|
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
| Flue gas COlow | |
|---|---|
|
Measuring range |
0 to 500 ppm |
|
Accuracy |
±5 % of mv (+40 to +500 ppm) ±2 ppm (0 to +39.9 ppm) |
|
Resolution |
0.1 ppm (0 to +500 ppm) |
|
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
| Flue gas NO | |
|---|---|
|
Measuring range |
0 to +4000 ppm |
|
Accuracy |
±5 % of mv (+100 to +1999 ppm) ±10 % of mv (+2000 to +4000 ppm) ±5 ppm (0 to +99 ppm) |
|
Resolution |
1 ppm (0 to +4000 ppm) |
|
Reaction time t₉₀ |
30 s |
| Flue gas Nolow | |
|---|---|
|
Measuring range |
0 to +300 ppm |
|
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
|
Resolution |
±0.1 ppm (0 to +300 ppm) |
|
Reaction time t₉₀ |
30 s |
| Flue gas NO₂ | |
|---|---|
|
Measuring range |
0 to +500 ppm |
|
Accuracy |
±5 % of mv (+100 to +500 ppm) ±5 ppm (0 to +99.9 ppm) |
|
Resolution |
0.1 ppm (0 to +500 ppm) |
|
Reaction time t₉₀ |
40 s |
| Flue gas SO₂ | |
|---|---|
|
Measuring range |
0 to +5000 ppm |
|
Accuracy |
±5 % of mv (+100 to +2000 ppm) ±10 % of mv (+2001 to +5000 ppm) ±5 ppm (0 to +99 ppm) |
|
Resolution |
1 ppm (0 to +5000 ppm) |
|
Reaction time t₉₀ |
30 s |
| Flue gas degree of effectivity, Eta (calculated) | |
|---|---|
|
Measuring range |
0 to +120 % |
|
Resolution |
0.1 % (0 to +120 %) |
| Flue gas loss (calculated) | |
|---|---|
|
Measuring range |
0 to +99.9 % |
|
Resolution |
0.1 % (0 to +99.9 %) |
| Flue gas dewpoint (calculated) | |
|---|---|
|
Measuring range |
0 to +99.9 °Ctd |
|
Resolution |
0.1 °Ctd (0 to +99.9 °Ctd) |
| Flue gas CO₂ calculation (calculated from O₂) | |
|---|---|
|
Measuring range |
0 to CO₂ max |
|
Accuracy |
calculated from O₂ ±0.2 Vol.% |
|
Resolution |
0.01 Vol.% |
| Flue gas H₂S | |
|---|---|
|
Measuring range |
0 to +300 ppm |
|
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
|
Resolution |
0.1 ppm (0 to +300 ppm) |
|
Reaction time t₉₀ |
35 s |
| Flue gas CO₂ - NDIR | |
|---|---|
|
Measuring range |
0 to +50 Vol.% |
|
Accuracy |
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%) ±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%) |
|
Resolution |
0.01 Vol.% (0 to 25 Vol.%) 0.1 Vol.% (> 25 Vol.%) |
|
Reaction time t₉₀ |
10 s |
| Velocity / Volume flow | |
|---|---|
|
Measuring range |
0 to +40 m/s |
|
Resolution |
0.1 m/s (0 to +40 m/s) |
| Methane (CH₄) | |
|---|---|
|
Measuring range |
100 to 40000 ppm |
|
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
|
Resolution |
10 ppm |
|
Min. O₂ requirement in flue gas |
2 % + (2 x mV methane) |
|
Reaction time t₉₀ |
< 40 s |
|
Response factor |
1 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
| Propane (C₃H₈) | |
|---|---|
|
Measuring range |
100 to 21000 ppm |
|
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
|
Resolution |
10 ppm |
|
Min. O₂ requirement in flue gas |
2 % + (5 x mV propane) |
|
Reaction time t₉₀ |
< 40 s |
|
Response factor |
1.5 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
| Butane (C₄H₁₀) | |
|---|---|
|
Measuring range |
100 to 18000 ppm |
|
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
|
Resolution |
10 ppm |
|
Min. O₂ requirement in flue gas |
2 % + (6.5 x mV butane) |
|
Reaction time t₉₀ |
< 40 s |
|
Response factor |
2 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
| General technical data | |
|---|---|
|
Weight |
4800 g |
|
Dimensions |
330 x 128 x 438 mm |
|
Operating temperature |
-5 to +45 °C |
|
Product-/housing material |
ABS |
|
Protection class |
IP40 |
|
Product colour |
Black |
|
Connectable probes |
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
|
Battery type |
lithium batteries |
|
Battery life |
5 h |
|
Power supply |
AC mains unit 100V to 240V (50 to 60 Hz) |
|
DC electric tension input |
11V to 40V |
|
Dewpoint calculation |
0 °Ctd; 99 °Ctd |
|
Max. dust load |
20 g/m³ dust in flue gas |
|
Max. neg. press./flue gas |