The testo 330i flue gas analyzer is an advancement of the testo 330 LL flue gas analyzer. Its proven measuring technology is once again at the heart of the testo 330i. This means that you can rely on highly accurate results when measuring flue gas, draught and O2 supply air. The testo 330i also has the following impressive features:
The new testoFix probe holder is available as an accessory, so the flue gas probe is guaranteed not to lose the centre of flow once it has been found. This can be attached to the pipe quickly and easily. It holds the probe in the centre of flow and also serves as a fall-proof suspension system for the testo 330i flue gas analyzer. Incidentally, the hose between probe and measuring instrument is lighter and more flexible than before.
The testo 330i no longer has a display. How do you make the correct adjustments to the flue gas analyzer? Where can you view the readings? What about the creation of measurement protocols? Via the testo 330i App on your smartphone. The readings are transferred from the testo 330i flue gas analyzer to the App via Bluetooth. So you always have the relevant values to hand whenever you need them. This is particularly useful when faced with larger systems or awkward measuring points as there is no need to look around corners, which can be annoying. The measurement parameters can also be set intuitively, via the App. Once you have completed the measurement, you can add comments or photos of the system to the results on site, and send them to your customer or the office via e-mail.
Requirement: iOS 7.1 / Android 4.3 or newer. Mobile end device with Bluetooth 4.0.
If you are looking for Testo 330i Flue Gas Analyzer Price in Bangladesh, Pico Labs Ltd. offers competitive pricing along with expert support. The device is perfect for professionals in HVAC/Clean Rooms, helping maintain energy efficiency, air quality, and regulatory compliance. Choose Testo 330i for smart performance, wireless freedom, and long-term reliability in every flue gas measurement.
Pico Labs Ltd. delivers trusted calibration and rental services for advanced electrical test and measurement instruments across Bangladesh. Customers benefit from our expert technical support, certified calibration, and cost-effective rental options — ensuring every project runs with accuracy, reliability, and professional excellence.
| Weight |
720 g (excluding battery) |
|---|---|
| Dimensions |
270 x 160 x 57 mm |
| Operating temperature |
-5 to +45 °C |
| Power supply |
Rech. batt. block 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A (optional) |
| System requirements |
requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0 |
| Maximum memory |
500000 readings |
| Storage temperature |
-20 to +50 °C |
| Measuring range |
0 to 300 hPa |
|---|---|
| Accuracy |
±1.5 % of mv (Remaining Range) ±1 % of mv (+50.1 to +100.0 hPa) ±0.5 hPa (0.0 to +50.0 hPa) |
| Resolution |
0.1 hPa |
| Measuring range |
0 to 21 Vol.% |
|---|---|
| Accuracy |
±0.2 Vol.% |
| Resolution |
0.1 Vol.% |
| Measuring range |
0 to 21 Vol.% |
|---|---|
| Accuracy |
±0.2 Vol.% |
| Resolution |
0.1 Vol.% |
| Measuring range |
0 to 15000 ppm |
|---|---|
| Accuracy |
±200 ppm or ±20 % of mv (0 to 15000 ppm) |
| Resolution |
1 ppm |
| Measuring range |
0 to 3000 ppm |
|---|---|
| Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
| Resolution |
1 ppm |
| Option | |
| Measuring range |
0 to 3000 ppm |
|---|---|
| Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
| Resolution |
1 ppm |
| Option | |
| Measuring range |
-9.99 to +40 hPa |
|---|---|
| Accuracy |
±1.5 % of mv (+3.01 to +40.00 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa |
| Resolution |
0.01 hPa |
| Measuring range |
-9.99 to +40 hPa |
|---|---|
| Accuracy |
±1.5 % of mv (+3.01 to +40.00 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa) |
| Resolution |
0.01 hPa |
| Measuring range |
-40 to +1200 °C |
|---|---|
| Accuracy |
±0.5 % of mv (Remaining Range) ±0.5 °C (0.0 to +100.0 °C) |
| Resolution |
0.1 °C (-40 t1 +999.9 °C) 1 °C (Remaining Range) |
| dependent on the thermocouple | |
| Measuring range |
-40 to +1200 °C |
|---|---|
| Accuracy |
±0.5 % of mv (Remaining Range) ±0.5 °C (0.0 to +100.0 °C) |
| Resolution |
1 °C (Remaining Range) 0.1 °C (-40 to +999.9 °C) |
| dependent on the thermocouple | |
| Measuring range |
0 to 120 % |
|---|---|
| Resolution |
0.1 % |
| Measuring range |
0 to 120 % |
|---|---|
| Resolution |
0.1 % |
| Measuring range |
0 to 99.9 % |
|---|---|
| Resolution |
0.1 % |
| Measuring range |
0 to 99.9 % |
|---|---|
| Resolution |
0.1 % |
| Measu ring range |
Display range 0 to CO₂ max |
|---|---|
| Accuracy |
±0.2 Vol.% |
| Resolution |
0.1 Vol.% |
| Measuring range |
Display range 0 to CO₂ max |
|---|---|
| Accuracy |
±0.2 Vol.% |
| Resolution |
0.1 Vol.% |
| Measuring range |
0 to 4000 ppm |
|---|---|
| Accuracy |
±20 ppm or ±10 % of mv (0 to 400 ppm) ±10 % of mv (2001 to 4000 ppm) ±5 % of mv (401 to 2000 ppm) |
| Resolution |
1 ppm |