The testo 310 has two measurement cells for O2 and CO, and a temperature sensor integrated into the flue gas probe. The gas sensors measure the exact oxygen and carbon monoxide content as well as the flue gas and ambient temperature. From these data, all relevant measurement parameters such as CO2 value, degree of effectively and flue gas loss are calculated. The instrument stands out thanks to its easy handling and simple menu structure. You can read off the measurement values confidently and conveniently from the well-lit display, even in bad light conditions. The fuels are stored not just as numbers, but are each described. At the top edge of the clear display, the symbols for the different measurement menus are always in view. The display and the dirt-insensitive keypad are clearly structured. Operation is very easy – even if you only have one hand free.
For professionals seeking comprehensive solutions in combustion measurement, the analyzer pairs perfectly with Pico Labs Ltd.’s calibration and rental services. Customers in Bangladesh can easily access this advanced equipment while ensuring compliance with industry standards.
Ensure accurate, fast, and reliable monitoring with the Testo 300 kit 1 Flue Gas Analyzer. Check Testo 300 kit 1 Flue Gas Analyzer Price in Bangladesh today and enhance operational efficiency in HVAC/Clean Rooms.
Offering top-tier calibration and rental services for electrical test and measurement equipment, Pico Labs Ltd. ensures precision, reliability, and expert support. Trusted by professionals across Bangladesh, we provide advanced tools and solutions for HVAC/Clean Rooms and other technical applications, empowering your operations with confidence and accuracy.
| Temperature - TC Type K (NiCr-Ni) | |
|---|---|
|
Measuring range |
-40 to +1200 °C |
|
Accuracy |
±0.5 °C (0.0 to +100.0 °C) ±0.5 % of mv (Remaining Range) |
|
Resolution |
0.1 °C (-40 to +999.9 °C) 1 °C (Remaining Range) |
| Differential Pressure - Piezoresistive | |
|---|---|
|
Measuring range |
-100 to +200 hPa |
|
Accuracy |
±0.5 hPa (0 to +50.0 hPa) ±1 % of mv (+50.1 to +100.0 hPa) ±1.5 % of mv (+100.1 to +200 hPa) |
|
Resolution |
0.01 hPa |
| Flue gas O₂ | |
|---|---|
|
Measuring range |
0 to 21 Vol.% |
|
Accuracy |
±0.2 Vol.% |
|
Resolution |
0.1 Vol.% |
| Differential Pressure flue gas Draught - Piezoresistive | |
|---|---|
|
Measuring range |
-9.99 to +40 hPa |
|
Accuracy |
±0.005 hPa (+0 to +0.1 hPa) ±0.02 hPa (+0.1 to +3.00 hPa) ±1.5 % of mv (3.01 to +40 hPa) |
|
Resolution |
0.001 hPa (0 to 0.1 hPa) 0.01 hPa (Remaining Range) |
| Flue gas degree of effectivity, Eta (calculated) | |
|---|---|
|
Measuring range |
0 to 120 % |
|
Resolution |
0.1 % |
| Flue gas loss (calculated) | |
|---|---|
|
Measuring range |
0 to 99.9 % |
|
Resolution |
0.1 % |
| Flue gas CO₂ calculation (calculated from O₂) | |
|---|---|
|
Measuring range |
Display range 0 to CO₂ max |
|
Accuracy |
±0.2 Vol.% |
|
Resolution |
0.1 Vol.% |
| Flue gas CO (without H₂-compensation) | |
|---|---|
|
Measuring range |
0 to 4000 ppm |
|
Accuracy |
±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
|
Resolution |
1 ppm |
| Ambient CO | |
|---|---|
|
Measuring range |
0 to 2000 ppm |
|
Accuracy |
±10 ppm (0 to 100 ppm) ±10 % of mv (101 to 2000 ppm) |
|
Resolution |
1 ppm |
| General technical data | |
|---|---|
|
Operating humidity |
15 to 90 %RH non-condensing |
|
Dimensions |
244 (including probe connection) x 98 x 59 LxWxH |
|
Operating temperature |
-5 to +45 °C |
|
Protection class |
IP40 |
|
Product colour |
black/orange |
|
Display type |
5.0" touch display, HD 1280*720 pixels, IPS (160 k) |
|
Power supply |
Rechargeable battery, USB mains unit |
|
Guarantee |
Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months |
|
Authorizations |
TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3 |
|
Warranty conditions |
testo.com/guarantee |
|
Memory |
1,000,000 measuring values |
|
Storage battery type |
Lithium ion battery |
|
Battery life |
10 h |
|
Storage temperature |
-20 to +50 °C |
|
Weight |
approximately 800 g |
|
Charging temperature |
0 to +45 °C |
| Differential Pressure 4 Pa measurement - Piezoresistive | |
|---|---|
|
Measuring Range |
-50 to +50 Pa |
|
Accuracy |
±0.3 Pa (< 10 Pa) ±3 % of mv (Remaining Range) |
|
Resolution |
0.1 Pa |