The Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, safely take True rms voltage and current measurements without test leads.
Unlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. Just slide the 17.8 mm open fork, the widest in the industry, over a conductor and read simultaneous voltage and current values. Or simultaneous frequency and current values. The open fork works with wires up to AWG 4/0 (120 mm2). Or, you can use the attached test leads to measure voltage DC to 1000 V.
Fluke T6 1000 Electrical Tester is a high-performance tool designed for accurate voltage, current, and continuity measurements. Its unique FieldSense™ technology allows safe, non-contact AC voltage detection, making it ideal for professionals in Electrical diagnostics. The tester features a large, easy-to-read display, durable design, and rapid response time for efficient troubleshooting. Reliable and precise, it ensures safety and efficiency in every measurement task. Check out the latest Fluke T6 1000 Electrical Tester Price in Bangladesh for the best deals.
Pico Labs Ltd. provides trusted calibration, testing, and rental services, delivering quality electrical solutions with professional support in Bangladesh.
| Measurement Specifications | ||||
|---|---|---|---|---|
| Function | Requires test leads | Range | Resolution | Accuracy[1] |
| FieldSense ac voltage true-rms |
No | 1000 V | 1 V | ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3] |
| FieldSense ac current true-rms |
No | 200.0 A | 0.1 A | ± (3% + 3 counts) 45 Hz - 66 Hz |
| FieldSense frequency (Hz) |
No | 45 Hz – 66 Hz | 1 Hz | ± (1% + 2 counts)[3] |
| Volts ac true-rms | Yes | 1000 V | 1 V | ± (1.5% + 2 counts) 45 Hz - 66 Hz |
| Volts dc | Yes | 1000 V | 1 V | ± (1% + 2 counts) |
| Resistance | Yes | 2000 Ω | 1 Ω | ± (1% + 2 counts) |
| Yes | 20.00 kΩ | 0.01 kΩ | ||
| Yes | 100.0 kΩ | 0.1 kΩ | ||
| Safety | 1000 V CAT III 600 V CAT IV |
|||
| Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding. Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
||||
| General Specifications | ||
|---|---|---|
| Calibration | 1-year calibration cycle | |
| Dimensions | 61.1 x 259.3 x 43.8 mm | |
| Jaw opening | 17.8 mm | |
| Weight | 0.35 kg (0.78 lb) | |
| Temperature | Operating | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage | -30 °C to +60 °C (-22 °F to +140 °F) | |
| Altitude | Operating | 2,000 m (6,562 feet) |
| Storage | 10,000 m (32,808 feet) | |
| Relative Humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) | |
| 0% to 75%, 30°C to 40 °C (86 °F to 104 °F) | ||
| 0% to 45%, 40°C to 50 °C (104 °F to 122 °F) | ||
| Battery Type and Life | 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense | |
| Temperature coefficient | 0.1 x (specified accuracy) / °C for <18°C or >28 °C | |
| 0.1 x (specified accuracy) / °C for <18°C or >28 °C | ||
| Safety | IEC/EN 61010-1: Pollution Degree 2 | |
| Electromagnetic Environment | IEC/EN 61326-1: Portable | |