Fluke 317 and 319 are designed gone ergonomic concepts, shaped to fit your hand and to admission tight a skin condition easily. These small and rugged clamp meters are ideally suited for current measurements in the range of 1000 A (319) in tight cable compartments.
The Fluke 317, as well as comes with features that the money for AC/DC measurements and has a highly developed conclusion for large quantities numb 40 A. In addition to a compact package once a hermetic feature set, the Fluke 319 moreover equips subsequent to In-hurry current and Frequency functions for analysis of motors, lighting, etc.
Fluke 317 Clamp Meters deliver precise electrical measurements with ease, making them ideal for electricians, engineers, and maintenance professionals. Designed for accuracy and reliability, these meters measure AC/DC, voltage, resistance, and continuity safely without interrupting the circuit. Compact and user-friendly, Fluke 317 ensures efficient troubleshooting and maintenance in industrial and residential settings. Looking for the latest Fluke 317 Clamp Meters Price in Bangladesh?
Pico Labs Ltd. offers competitive rates along with rental services for all your electrical testing needs. Enhance your projects with quality instruments and flexible solutions provided by Pico Labs Ltd., your trusted partner in electrical rentals.
| General specifications | |
| Digital display | 6000 count resolution |
| Low battery Indication | Displays a signal when the batteries are below their required voltage |
| Power source | Three AAA IEC LR03 batteries |
| Clamp opening size | 1.45 in (37 mm) |
| Jaw diameter | 1.45 in (37 mm) |
| Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in |
| (162.4 x 58.25 x 30.5 mm) | |
| Weight | Approximately 13.5 oz (384 g) (batteries included) |
| Auto range | Available in Ohms |
| Safety | CE |
| EN/IEC 61010-1 and IEC 61010-2-032 | |
| Measurement Category: 600V CAT III | |
| 317 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω, 4000 Ω |
| Resolution | 0.1 Ω, 1 Ω | |
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | N/A |
| Frequency | Range | N/A |
| Accuracy | N/A | |
| Trigger Level | N/A | |
| 319 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600/1000 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω |
| 4000 Ω | ||
| Resolution | 0.1 Ω | |
| 1 Ω | ||
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | 100 ms |
| Frequency | Range | 5.0 - 500.0 Hz |
| Accuracy | 0.5% ±5 digit | |
| Trigger Level | 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A | |
| The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
||
| Environmental specifications | |
| Operating temperature | 14°F to 122°F (-10 °C to 50 °C) |
| Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
| Operating humidity | Non-condensing (< 50 °F) (< 10 °C) |
| 90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |
| 75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |
| 45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |
| (Without condensation) | |
| Operating altitude | 1 mile (2000 meters) above mean sea level |
| Storage altitude | 7 miles (12,000 meters) above mean sea level |
| IP Rating | IP40 |
| Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
| Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor |
| EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m |
| Temperature coefficients | 0.1x (specified accuracy)/ °C |
| (<64 °F or > 82° F) | |
| (<18 °C or > 28 °C) | |