Prevent unplanned downtime by detecting leakage currents with the ALC-110 Leakage Current Clamp. Rated CAT III 600 V to ensure electrical safety, the ALC-110 is designed to resist external magnetic fields for highly accurate readings. Features TRMS, a mechanical jaw lock, max readings and hold functions, highest resolution of 0.001 mA (measure up to 60 A), broad frequency range (15 Hz to 1 kHz), selectable filters (low pass, appliance, no filter), selectable limits (0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA) and a battery-saving design.
Discover the precision and reliability of the Amprobe ALC-110 Leakage Current Clamp, designed for accurate leakage current measurements in electrical systems. Ideal for electricians and maintenance professionals, it ensures safety and efficiency in troubleshooting and preventive maintenance. Available at competitive rates, the Amprobe ALC-110 Leakage Current Clamp Price in Bangladesh offers great value for both purchase and rental options. Pico Labs Ltd. provides top-quality rental electrical products, making advanced tools like the ALC-110 accessible for short-term projects. Benefit from expert support, flexible rental plans, and cost-effective solutions for all your electrical testing needs with Pico Labs Ltd.
| Low frequency magnetic fields | ≤ 30 A/m, operating class 2 @ IN : 3.500 mA to 600.0 mA / 40 Hz to 1 kHz |
| Measurement category | CAT III 600 V |
| True-rms | Yes |
| AC frequency | 15 Hz to 1 kHz |
| Low pass filter | 50 – 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter |
| Limit judgement | 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA |
| Jaw opening | 1.2 in (30 mm) max. |
| Jaw locking | Yes |
| Backlight function | Yes |
| Overload protection | 60 A |
| Auto power off | Idle 20 minutes |
| Auto ranging | Yes |
| Max hold | Yes |
| Data hold | Yes |
| Complies with IEC/EN 61557-13 | Yes |
| Built according IEC/EN 61010-2-032 | Yes |
| General Specifications | |
| Display | Digital: 6000 counts, updates 5/sec |
| Range | Auto-ranging |
| Over range indication | OL or -OL |
| Operating temperature | 32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH 86 °F to 104 °F (30 °C to 40 °C), ≤ 75% RH 104 °F to 122 °F (40 °C to 50 °C), ≤ 45% RH |
| Operating altitude | ≤ 2000 m |
| Storage temperature | -4 °F to 140 °F (-20 °C to 60 °C) |
| Pollution degree | 2 |
| Temperature coefficient | 0.1 x (specified accuracy) / °C (<21 °C, <25 °C) |
| Vibration requirement | acc. IEC 61557-1 clause 4.10 |
| Drop proof | 4 ft (1.2 m) |
| Battery | 2x batteries 1.5 V IEC LR03 AAA |
| Battery life | 60 hours typical |
| Safety compliance | IEC/EN 61010-1, IEC/EN 61010-2-030, IEC/EN 61010-2-032, IEC/EN 61557-13 |
| EMC compliance | IEC/EN 61326-1, IEC/EN 61326-2-2 |
| Dimensions (H x W x L) | 8.7 x 3.5 x 1.8 in (221 x 89 x 48 mm) |
| Weight | 0.9 lb (410 g) with batteries installed |