Amprobe ACD-41PQ 1000A Power Quality Clamp Meter True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout and also it's working accurately that are rugged reliable and trusted.
The Amprobe ACD-40 provides an easily reached and in goings-on habit to post if the electrical system is affected by harmonics.
Add on the order of troubleshooting capabilities taking into account the ACD-40PQ data-logging feature or get a bond of unconditional knack analysis following the ACD-41PQ. Increase measuring efficiency taking into consideration an optional PC interface kit.
THD-F is defined as (Total Harmonic RMS / Fundamental RMS) x 100%
Pico Labs Ltd. offers reliable rental solutions for high-quality electrical products, ensuring efficient operations for businesses across Bangladesh. Professional calibration services guarantee accurate and precise measurements for all instruments. Trusted by industry leaders, Pico Labs Ltd. combines affordability, quality, and expert support to meet your electrical equipment needs seamlessly.
| FEATURE | ACD-41PQ | ACD-45PQ |
| True-rms | • | |
| AC Current | 40.00 A, 400.0 A, 1000 A | 40.00 A, 400.0 A, 600 A |
| AC/DC Voltage | 600.0 V | |
| Resistance | 999.9 Ω | |
| Continuity | • | |
| Temperature | -58 °F → 572 °F (-50 °C → 300 °C) | – |
| Frequency | 5.00 Hz → 500.0 Hz | |
| Active power | (W) 0 kW → 600.0 kW | 0 kW → 360.0 kW |
| Reactive power (VAR) | 0 kVAR → 600.0 kVAR | 0 kVAR → 360.0 kVAR |
| Apparent power (VA) | 0 kVA → 600.0 kVA | 0 kVA → 360.0 kVA |
| Power Factor | 0.10 → 0.99 | |
| Energy (KWHr) | • | • |
| Total Harmonic Distortion (THD%) | 0.0 % → 99 % | – |
| Accommodates Conductors | up to 1.77″ (45 mm) in diameter | up to 1.02″ (26 mm) in diameter |
| Specifications | |
| TRMS: | YES |
| AC Current: | 40.0 / 400.0 / 1000 A |
| AC Current Basic Accuracy: | +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
| DC Voltage: | 600.0V |
| DC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) |
| AC Voltage: | 600.0V |
| AC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
| Resistance: | 999.9O |
| Resistance Basic Accuracy: | +/-(1.0% Rdg + 6 LSD) |
| Frequency: | 5.00Hz to 500.0Hz |
| Frequency Basic Accuracy: | +/-(0.5% Rdg +4 LSD) |
| THD-F *: | 0.0% to 99.9% |
| THD-F * Basic Accuracy**: | 1.5% of Reading + 6d @ Fund Frequency |
| Active Power (W): | 0 to 600.0 kW |
| Active Power (W) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
| Reactive Power (VAR): | 0 to 600.0 kVAR |
| Reactive Power (VAR) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
| Apparent Power (VA): | 0 to 600.0 kVA |
| Apparent Power (VA) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
| Power Factor: | 0.10 to 0.99 |
| Power Factor Basic Accuracy: | +/- 3 LSD @ Harmonics Fund to 21th |
| Temperature: | -58°F to 572° F (-50° C to 300° C) |
| Temperature Basic Accuracy: | +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C) |