Get Support

+8801977426642

HIOKI DT4281 DIGITAL MULTIMETER

  • Home
  • HIOKI DT4281 DIGITAL MULTIMETER

The HIOKI DT4281 Digital Multimeter is a high-precision measuring instrument designed for professional electrical testing and maintenance. Featuring advanced True RMS measurement, this multimeter delivers accurate voltage, current, and resistance readings in complex AC/DC circuits. Its robust design ensures durability for both industrial and field applications, while the intuitive interface and large LCD display simplify measurement tasks. The device also includes continuity testing, diode testing, and capacitance measurement, making it a versatile tool for engineers and technicians. Safety is ensured with CAT IV 600V/CAT III 1000V ratings, protecting users in demanding electrical environments. With its compact form factor and efficient power management, the HIOKI DT4281 Digital Multimeter combines precision, safety, and convenience in a single device.

For professionals searching for reliable electrical measurement tools, the HIOKI DT4281 Digital Multimeter Price in Bangladesh offers a cost-effective solution without compromising quality. Explore Pico Labs Ltd. for premium equipment rental and calibration services to ensure peak performance of all your measurement devices.

Pico Labs Ltd. provides top-quality rental electrical products and expert calibration services across Bangladesh. Reliable, timely, and professional, our solutions help businesses maintain precise measurements and ensure operational safety. Trust Pico Labs Ltd. for cutting-edge equipment, including digital multimeters, with unmatched service and support tailored to your needs.

Key Features:

  • 60000 count, 5-digit display, high-resolution measurements
  • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
  • The low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
  • Terminal shutter mechanism (prevents erroneous test lead insertion)
  • The dual display lets you check voltage and frequency simultaneous

Specifications:

Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to a DMM's many ranges and functions, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.

DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage* range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC Voltage* range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC Current range 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC Current* range 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current* range
(use with Clamp on probes)
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy 40 - 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3)
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated)
Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature (thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion
Display Main and sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
Included accessories Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4

Customer Reviews