Get Support

+8801977426642

HIOKI DT4261 DIGITAL MULTIMETER

  • Home
  • HIOKI DT4261 DIGITAL MULTIMETER

The HIOKI DT4261 Digital Multimeter is a high-precision measurement tool designed for both professionals and advanced technicians. Equipped with a clear, large LCD display, it ensures accurate readings for voltage, current, resistance, continuity, and capacitance. Its compact and ergonomic design provides easy handling during fieldwork or laboratory tasks. The DT4261 also features a robust safety standard compliance, ensuring protection while measuring high voltages. With fast response times and reliable accuracy, it is ideal for troubleshooting electrical circuits and performing routine inspections. The multimeter offers user-friendly functionalities, including data hold, peak hold, and auto-ranging modes, enhancing efficiency and convenience. For professionals seeking dependable performance, the HIOKI DT4261 Digital Multimeter stands out as a durable and versatile solution.

Check the HIOKI DT4261 Digital Multimeter Price in Bangladesh at Pico Labs Ltd., where premium electrical tools meet expert rental and calibration services. For more details, explore our range of Digital Multimeter solutions and elevate your electrical testing experience.

Pico Labs Ltd. provides reliable rental electrical products and professional calibration services across Bangladesh. Customers benefit from high-quality tools, timely service, and expert support, ensuring accurate measurements and efficient operations. Trust Pico Labs Ltd. for all your electrical testing needs, from short-term rentals to long-term equipment solutions.

Key Features:

  • Enables high voltage measurement up to CAT III 2000 V
  • - Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)
  • CAT III 1000 V, CAT IV 600 V

Specifications:

Accuracy guaranteed: 1 year
DMM Accuracy: Due to a DMM's many ranges and functions, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.

DC Voltage range 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt.
AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 Hz - 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
DC + AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
LoZ V 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
Resistance range 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt.
DC Current range 600.0 mA to 10.00 A, 3 ranges
Basic accuracy: ±0.5% rdg. ±3 dgt.
AC Current range 600.0 mA to 10.00 A, 3 ranges
Basic accuracy 40 Hz - 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
Frequency characteristics: 40 Hz to 1 kHz
AC Current range (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges
Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance range 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt.
Continuity Check Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more
Diode test Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
Voltage frequency range 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Current frequency range 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Harmonic levels [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other functions Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
Display Main and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s)
Power supply LR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications)
Dimensions and mass 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries)
Included accessories Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1