The HIOKI DT4255 Digital Multimeter is a high-performance, compact device designed for precise electrical measurements. Engineered for professionals, it offers true RMS measurement, ensuring accurate voltage, current, and resistance readings even in complex waveforms. With a large backlit display and ergonomic design, the DT4255 allows effortless handling and readability in various environments. Its advanced features include continuity testing, diode testing, capacitance measurement, and temperature monitoring, making it a versatile tool for both industrial and laboratory applications. Safety is ensured with CAT III 600V and CAT IV 300V ratings, providing reliable protection during high-voltage testing. Users benefit from fast response time and data hold functions, enhancing efficiency during troubleshooting or calibration tasks. The durable construction ensures long-lasting performance under rigorous use.
For professionals and hobbyists in Bangladesh, checking the HIOKI DT4255 Digital Multimeter Price in Bangladesh is now easier, and the device can be integrated into any electrical maintenance or testing workflow. For more insights and comparisons, explore our range of Digital Multimeter options to select the perfect solution for your needs.
Pico Labs Ltd. delivers reliable electrical product rentals and expert calibration services across Bangladesh. Equipment is maintained to the highest standards, ensuring precise and safe operations. Professionals trust Pico Labs Ltd. for flexible rental options, expert guidance, and rapid service, making electrical testing and maintenance more efficient and cost-effective.
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to a DMM's many ranges and functions, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. |
|||||
|---|---|---|---|---|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
|||||
| AUTO AC/DCV | Yes | |||||
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. | |||||
| DC Current range | N/A | |||||
| From 4 to 20mA Percentage conversion display | N/A | |||||
| AC Current range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) | |||||
| Temperature (thermocouples) |
N/A | |||||
| Voltage detection | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V | |||||
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. | |||||
| Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
|||||
| Continuity check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
|||||
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
|||||
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) | |||||
| Display | Main and Sub displays: 4-digit LCD, max. 6000 digits, bar graph | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) | |||||
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) | |||||
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
|||||
| Included accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 | |||||