The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4253 is a digital multimeter designed specifically for HVAC testing, with ±0.5% DC V accuracy, temperature and clamp sensor testing, and wide 40 Hz to 1 kHz bandwidth.

CAT IV 600 V, CAT III 1000 V

Reliable solutions for all your electrical needs, Pico Labs Ltd. offers top-quality rental electrical products and professional calibration services across Bangladesh. Ensuring precision, safety, and efficiency, our expert team supports industries and professionals with trusted equipment and timely service. Experience convenience, accuracy, and excellence with Pico Labs Ltd.

Key Features

  • Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
  • Dual display lets you check voltage and frequency simultaneously
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)

Specifications

DC Voltage range 600.0 mV to 1000 V
5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt.
AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
AUTO AC/DCV Yes
Resistance range 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.
DC Current range 60.00 μA to 60.00 mA, 4 ranges,
Basic accuracy: ±0.8 % rdg. ±5 dgt.
From 4 to 20mA Percentage conversion display Yes
AC Current range (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Temperature (thermocouples) K: -40.0 to 400.0 °C , Add the Temperature probe accuracy to basic accuracy: ±0.5 % rdg. ±2 °C
Voltage detection N/A
Capacitance range 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency range 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less ,
[OFF]: 245 Ω or more,
Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)