Fluke 724 Temperature Calibrator offers anything you habit to troubleshoot and calibrate temperature
The Fluke 724 is powerful yet easy-to-use temperature calibrator that sources and proceedings 10 thermocouple types, and 7 RTD types, benefit volts and ohms. It along with events mA though supplying loop do something. You can use it to test and calibrate not in the disaffect off from any temperature instrument hence you without help have to carry one tool to proficiently exam all the temperature sensors and transmitters in your reforest.
The Fluke 724 even handles tall-eagerness pulsed RTD circuits and provides loop gaining. The dual-lineage function/source display lets you source temperature and views loop current at the related become antique. And once its easy to performance to, "no menus controls, you'll be responsive to benefit all your psychoanalysis ended faster.
Fluke 724 is not only a temperature calibrator but with the value of this product you can't unbelievable upon the workplace what is giving the disquiet on. Check out it from Tools Bangladesh.
| Measurement Accuracy | ||
| Voltage DC | 30.000 V | 0.02% + 2 counts (upper display) |
| 20.000 V | 0.02% + 2 counts (lower display) | |
| 100.00 mV | 0.02% + 2 counts | |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC | 24.000 mA | 0.02% + 2 counts |
| Resistance | 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
| 401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) | |
| 1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) | |
| Source Accuracy | ||
| Voltage DC | 100.00 mV | 0.02% + 2 counts |
| 10.000 V | 0.02% + 2 counts | |
| -10.00 mV to 75.00 mV | 0.025 % + 1 count (via TC connector) | |
| Resistance | 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
| 401 to 1500 Ω | 0.5 Ω (excitation current 0.05 to 0.8 mA) | |
| 1500 to 3200 Ω | 1 Ω (excitation current 0.05 to 0.4 mA) | |
| RTDs and Thermocouples | ||
| Measure accuracy | NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C | |
| PT-100 (393) | 0.3°C | |
| PT-100 (JIS) | 0.3°C | |
| PT-200 (385) | 0.2°C | |
| PT-500 (385) | 0.3°C | |
| PT-1000 (385) | 0.2°C | |
| Resolution | 0.1°C | |
| J | 0.7°C | |
| K | 0.8°C | |
| T | 0.8°C | |
| E | 0.7°C | |
| R | 1.8°C | |
| S | 1.5°C | |
| B | 1.4°C | |
| L | 0.7°C | |
| U | 0.75°C | |
| N | 0.9°C | |
| Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
| XK | 0.6°C | |
| BP | 1.2°C | |
| Source accuracy | NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C | |
| PT-100 (393) | 0.3°C | |
| PT-100 (JIS) | 0.3°C | |
| PT-200 (385) | 0.2°C | |
| PT-500 (385) | 0.3°C | |
| PT-1000 (385) | 0.2°C | |
| Resolution | 0.1°C | |
| Accuracy stated for 4-wire measurement. | ||
| J | 0.7°C | |
| K | 0.8°C | |
| T | 0.8°C | |
| E | 0.7°C | |
| R | 1.4°C | |
| S | 1.5°C | |
| B | 1.4°C | |
| L | 0.7°C | |
| U | 0.75°C | |
| N | 0.9°C | |
| Resolution | J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C | |
| XK | 0.6°C | |
| BP | 1.2°C | |
| Specifications | ||
| Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
| Loop power function | Voltage | 24 V |
| Accuracy | 10% | |
| Maximum current | 22 mA, short circuit protected | |
| Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Steps | 25% of range, 100% of range | |
| Environmental Specifications | ||
| Operating temperature | -10°C to 55°C | |
| Storage temperature | -20°C to 71°C | |
| Humidity (without condensation) | 90% | 10°C to 30°C |
| 75% | 30°C to 40°C | |
| 45% | 40°C to 50°C | |
| 35% | 50°C to 55°C | |
| Safety Specifications | ||
| Safety rating | CSA C22.2 No. 1010.1:1992 | |
| EMC | EN50082-1:1992 and EN55022:1994 Class B | |
| Mechanical and General Specifications | ||
| Size | 96 x 200 x 47 mm | |
| Weight | 650 g | |
| Batteries | Four AA alkaline batteries | |
| Warranty | Three years | |
| Battery life | 25 hours typical | |
| Shock and vibration | Random, 2 G, 5-500 Hz | |