Fluke 7060, 7080 Really Cold Temperature Calibration Baths

  • Home
  • Fluke 7060, 7080 Really Cold Temperature Calibration Baths

Fluke 7060/7080 Really Cold Temperature Calibration Baths

These baths are completely self-contained. They require no auxiliary cooling fluids or devices to achieve their set-point temperatures. Using Fluke Calibration's unique "heat-port" design, stability at –80 °C is ±0.0025 °C. No other company makes a bath that can match a Fluke Calibration bath’s performance, and Fluke Calibration baths are backed by our guarantee that if they don’t perform exactly the way we say they will, we’ll take them back. No arguments. No ifs, ands, or buts. If you want to completely automate the entire calibration process, see the description of Fluke Calibration's MET/TEMP II software package.

Forget commodity-like utility baths! They’re not designed for high performance calibration needs. And be careful of companies that advertise performance specifications they don’t meet. It’s easy to write down numbers; it’s more difficult to meet them with an instrument. Remember, if our baths don’t perform the way we say they will, just send them back. Our equipment won’t disappoint you.

Key Features: Fluke 7060/7080 Really Cold Temperature Calibration Baths

  • Ability to chill to extremely low temperatures (–40, –60, or –80 °C) without external coolants.
  • Self-contained refrigeration, eliminating the need for LN2 or a chiller.
  • Large working areas for increased throughput.
  • Provides excellent temperature control, maintaining stability (±0.0015 °C) and uniformity (±0.003 °C) even at extremely cold temperatures.

Specifications: 7060/7080 Really Cold Temperature Calibration Baths

Specifications 7060 7080
Range −60 °C to 110 °C −80 °C to 110 °C
Stability ±0.0025 °C at −60 °C (methanol)
±0.002 °C at 0 °C (methanol)
±0.0015 °C at 25 °C (water)
±0.003 °C at 100 °C (oil 5012)
±0.0025 °C at −80 °C (methanol)
±0.0015 °C at 0 °C (methanol)
±0.0015 °C at 25 °C (water)
±0.003 °C at 100 °C (oil 5012)
Uniformity ±0.005 °C at −60 °C (methanol)
±0.005 °C at 0 °C (methanol)
±0.003 °C at 25 °C (water)
±0.005 °C at 100 °C (oil 5012)
±0.007 °C at −80 °C (methanol)
±0.005 °C at 0 °C (methanol)
±0.003 °C at 25 °C (water)
±0.005 °C at 100 °C (oil 5012)
Temperature Setting Digital display with push-button data entry
Set-Point Resolution 0.01 °C; high-resolution mode, 0.00007 °C
Display Resolution 0.01 °C
Digital Setting Accuracy ±1 °C
Digital Setting Repeatability ±0.01 °C
Heaters 500 and 1000 Watts
Access Opening 127 x 254 mm (5 x 10 in)
Depth 305 mm (12 in)
Wetted Parts 304 stainless steel
Power 230 VAC (±10 %), 50 or 60 Hz, 13 A, single phase, specify frequency
Volume 27 liters (7.2 gallons)
Weight 159 kg (350 lb.)
Size (HxWxD) 1168 x 775 x 483 mm (46 x 30.5 x 19 in)
Automation Use the 1586A Super-DAQ to automate temperature sensor calibration