Fluke 1502A Tweener Thermometer ReadoutsOne of Fluke Calibration's best-selling products is the Tweener thermometer, and theres a reason. No toting happening company, not one, has a mention thermometer that comes stuffy to the comport yourself and features of the Tweener for anywhere near its price.
The best things roughly Tweener Thermometer Readouts that not on your own always have enough maintenance accurate results but along with the value of this Fluke product always spot on the subject of.
We Iconic Engineering offers the best and dexterously-behaved Tweener Thermometer Readouts through Tools Bangladesh behind affordable price. Keep it and acquire the best product that you are always looking for.
Specifications |
1502A | 1504 |
| Temperature Range† | −200 °C to 962 °C (−328 °F to 1764 °F) | Any thermistor range |
| Resistance Range | 0 Ω to 400 Ω, auto-ranging | 0 Ω to 1 MΩ, auto-ranging |
| Probe | Nominal RTPW: 10 Ω to 100 Ω RTD, PRT, or SPRT |
Thermistors |
| Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 IPTS-68: R0, a, d, a4, and c4 Callendar-Van Dusen: R0, a, d, and b |
Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b |
| Resistance Accuracy (ppm of reading) |
0 Ω to 20 Ω: 0.0005 Ω 20 Ω to 400 Ω: 25 ppm |
0 Ω to 5 KΩ: 0.5 Ω 5 KΩ to 200 KΩ: 100 ppm 200 KΩ to 1 MΩ: 300 ppm |
| Temperature Accuracy† | ±0.004 °C at −100 °C ±0.006 °C at 0 °C ±0.009 °C at 100 °C ±0.012 °C at 200 °C ±0.018 °C at 400 °C ±0.024 °C at 600 °C |
±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.) |
| Operating Temperature Range | 16 °C to 30 °C | 13 °C to 33 °C |
| Resistance Resolution | 0 Ω to 20 Ω: 0.0001 Ω 20 Ω to 400 Ω: 0.001 Ω |
0 Ω to 10 KΩ: 0.01 Ω 10 KΩ to 100 KΩ: 0.1 Ω 100 KΩ to 1 MΩ: 1 Ω |
| Temperature Resolution | 0.001 °C | 0.0001 °C |
| Excitation Current | 0.5 and 1 mA, user selectable, 2 Hz | 2 and 10 µA, automatically selected |
| Measurement Period | 1 second | |
| Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) | |
| Probe Connection | 4-wire with shield, 5-pin DIN connector | |
| Communications | RS-232 serial standard IEEE-488 (GPIB) optional |
|
| Display | 8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters | |
| Power | 115 VAC (±10 %), 50/60 Hz, 1 A, nominal 230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify |
|
| Size (HxWxD) | 61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) | |
| Weight | 1.0 kg (2.2 lb.) | |
| Probes from Fluke Calibration | 5615, 5627, 5626, 5628, 5622 | 5640-44, 5610-65 |
| Calibration | ISO 17025-accredited calibration provided | |
| †Temperature ranges and accuracy may be limited by the sensor you use. | ||