Amprobe 35XP-A Digital Multimeter with Temperature is a good performing buyThis measurement capability to 1000 °C/1832 °F with all including features that are reliable and trusted
Amprobe compact 35XP-A Digital Multimeter offers all the right features for HVAC and plant maintenance. It measures temperature, plus capacitance for a motor run/start test, and offers 0.1 µA resolution for flame sensor testing.
Pico Labs Ltd. offers reliable rental electrical products and professional calibration services across Bangladesh. With a focus on accuracy, affordability, and customer satisfaction, we ensure your equipment performs at its best. Choose Pico Labs Ltd. for trusted solutions that save time, reduce costs, and keep your operations running smoothly.
| FEATURE | 35XP-A |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V |
| AC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V |
| Current AC/DC | 400.0 µA, 4.000 µA, 40.00 mA, 400.0 mA, 2 A |
| Resistance | 40.00 kΩ, 400.0 kΩ, 4.000 MΩ. 40.00 MΩ |
| Continuity beeper | ✓ |
| VolTect™ Non-Contact Voltage Detection | 70 VAC → 600 VAC (50 Hz → 60 Hz) |
| Capacitance | 4.000 nF, 40.00 nF, 4.000 µF, 40.00 µF, 400.0 µF, 4.000 mF |
| Frequency | 4,000 kHz, 40.00 kHz, 400,0 kHz, 1 MHz |
| Temperature | -4 °F → 1832 °F (-20 °C → 1000 °C) |
| Logic test | – |
| Battery test | – |
| Specifications | |
| DC Volts range: | 400 mV, 4 V, 40 V, 400 V, 600 V Accuracy: ± (0.5 % rdg + 1 dgts) |
| AC Volts (45 Hz to 500 Hz) range: | 400 mV (45 Hz to 100 Hz) 4 V, 40 V, 400 V, 600 V (45 Hz to 500Hz) Accuracy: ± (1.5 % rdg + 5 dgts) |
| Voltage resolution: | 100 µV |
| Input impedance: | 400 mV: >100 MΩ ; 4 V: 10 MΩ ; 40 V to 600 V: 9.1 MΩ |
| Overload protection: | 600 V dc or 60 V ac rms |
| DC Current range: | 400 µA, 4000 µA, 40 mA, 400 mA ± (1.0 % rdg + 2 dgt) |
| DC Current range: | 2 A ± (2.0 % rdg + 3 dgts) |
| AC Current (45 Hz to 500 Hz) range: | 400 µA, 4000 µA, 40 mA, 400 mA ± (1.5 % rdg + 5 dgts) |
| AC Current (45 Hz to 500 Hz) range: | 2 A ± (2.5 % rdg + 5 dgts) |
| Current resolution: | 0.1 µA |
| Input protection: | 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input |
| Burden voltage: | 500 mV max. (2 V max. on 4 mA, 400 mA ranges) |
| Resistance: | 400 Ω , 4 kΩ , 40 kΩ , 400 kΩ , 4 MΩ ± (1.0 % rdg + 4 dgts) |
| Resistance: | 40 MΩ ± (2.0 % rdg + 5 dgts) |
| Resistance resolution: | 100 mΩ |
| Open circuit voltage: | -0.45 V dc typical, (-1.2 V dc on 400 Ω range) |
| Overload protection: | 600 V dc or 600 V ac rms |