Accurate data, delivered amazingly fast
Shorter test time on the 8588A/8558A high-speed digital platform enables you to increase throughput, improve yield, and realize a greater return on your investment. The 8588A/8558A digitizes to memory at 200 nanoseconds per reading and delivers 4.5 digit data to a PC via USB, Ethernet, and GPIB at 100,000 readings per second. Fast, high-resolution data capture gives you the quantity and quality of information you need to make timely, correct decisions affecting system throughput and efficiency.
- 0 ns to 100 s aperture setting allows the industry’s widest flexibility to control data capture window
- Reading speed: 1 reading /s @ 8.5 digits to 100,000 reading /s @ 4.5 digits
- Data transfer from memory to PC: up to 500,000 readings /s in binary format through USB, up to 200,000 through Ethernet and GPIB
Debug and perfect your device under test
The 8558A features a 5 mega-sample digitizing rate with up to 20 MHz analog bandwidth, making it the first and only instrument on the market that can characterize extremely low-level transient signals at 18-bit resolution. This capability makes it easier to debug designs, uncover anomalies, and perfect your devices under test for use in real-life environments.
- Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you to uncover ultra-low level transient signals
- Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
- 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
- 5 mega-samples per second sample rate, into the buffer, for capturing the complex, fast-changing waveforms
- 15 million readings memory allows a large amount of data storage eliminating the
- immediate need to transfer data to a PC
- Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers
Fast, reliable and accurate system compatibility
Inserting a new instrument into a tightly synchronized system can create overhead and incompatibility. The 8558A’s digital platform includes common connectivity interfaces plus precise triggering that lets it digitize, integrate, and transfer data anywhere in the system for analysis, with minimal obstruction and the highest reliability.
- GPIB, USBTMC, Ethernet allows industry-standard selection of remote interface
- USB thumb drive enable quick and easy data transfer to PC in .csv format
- SCPI compliant commands with 8505A and 3458A emulation mode simplify and accelerate system upgrade process to 8588A/8558A
- Fully supports MET/CAL calibration procedures library that commands the Fluke 8508A
- IVI Driver for industry-standard control of DMM on 8558A/8588A
- Trigger Mechanisms: External BNC Trigger Trig In and Trig Out, Edge or level trigger, Timer trigger, Epoch trigger, Line trigger
- Less than 100 ns trigger latency with external BNC trigger for digitizing voltage and current
Trigger System
Usability features ease training and operation
Some popular system digit multimeters have complex menu structures and unintuitive commands, while others lack any user interface, presenting barriers to training and operation. By contrast, the 8558A features an easy-to-access configuration menu that makes it easy to train new users. Language choices include English, Chinese, French, German, Japanese, Korean, Russian and Spanish. The graphical display lets you easily visualize trends, histograms, complex waveforms, and statistics. Repeatable system-specific tasks can be automated quickly and easily.
The 8558A’s front panel features Visual Connection Management™ output terminals that light up to show which terminals are active, guiding the user to make the correct connections. The handles and spin wheels are over-molded for comfort and easy transport.
USB host ports are placed both on the front and rear of the unit. Use them to export data to external memory devices and simplify firmware updates.
Analyze: Histogram
The MET/CAL™ Calibration Management Software advantage
The 8588A and 8558A work with Fluke Calibration MET/CAL™ Calibration Software with native MET/CAL support or using 8508A emulation mode to increase throughput up to four times that of traditional manual and multi-product methods while ensuring calibrations are performed consistently every time. This powerful software documents calibration procedures, processes and results for ease in complying with ISO 17025 and similar quality standards.
Support and services when you need them
Fluke Calibration offers testing, repair, and calibration services to meet your needs quickly and at a fair cost while maintaining a high level of quality that you expect. Our electrical calibration laboratories are accredited for conformance to ISO/IEC Guide 17025 and we maintain global calibration and repair facilities.
Get peace of mind and uptime with a Gold CarePlan service package
The 8588A/8558A multimeters come with a standard one-year factory warranty. You can enhance warranty protection with a Priority Gold Instrument CarePlan service package.
A Priority Gold Instrument CarePlan includes an expedited annual calibration to reduce downtime by a week and extended warranty to help ensure the best long-term performance from your instruments. Choose from one-year, three-year, or five-year Care- Plans. (Note: Priority shipping times vary by country. Contact your local Fluke Calibration sales representative for details.)
Key feature and specification comparison
8558A | 8588A | |
---|---|---|
DC voltage | 100 mV – 1000 V | 100 mV – 1000 V |
AC voltage | 10 mV – 1000 V, 1 Hz – 10 MHz | 10 mV – 1000 V, 1 Hz – 10 MHz |
Resistance, LoI, HV | 1 Ω – 10 GΩ | 1 Ω – 10 GΩ |
DC current | 10 uA – 2 A | 10 uA – 30 A |
AC current | 10 uA – 2A, 1 Hz to 100 kHz | 10 uA – 30 A, 1 Hz to 100 kHz |
Digitize V | 100 mV – 1000 V, 5 MSamples/s, up to 20 MHz BW | 100 mV – 1000 V, 5 MSamples/s, up to 20 MHz BW |
Digitize I |
10 uA – 2 A, 5 MSamples/s,
up to 4 MHz BW
|
10 uA – 30 A, 5 MSamples/s, up to 4 MHz BW |
Frequency (V, I, BNC) | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz |
Temperature | PRT / Thermocouple (ext CJC) | PRT / Thermocouple (ext CJC) |
Capacitance | No | 1 nF – 100 mF |
RF power | No | R&S NRP Series |
Ext. dc current and ac current | No | A40B current shunt and other shunts |
Graphical display | Yes | Yes |
Visual Connection Management ® | Yes | Yes |
Programmable front/rear input switching | Yes | Yes |
Ratio difference, deviation – ohms, voltage | Yes | Yes |
External 10 MHz ref clock, 50 Ω/Hi-Z | Yes | Yes |
A40B and other shunt asset management | No | Yes |
GPIB 488.2, Ethernet, USB TMC | Yes | Yes |
SCPI command compatibility | Yes | Yes |
3458A emulation, 8508A emulation | Yes | Yes |
Memory | 15 million | 15 million |
Level and another trigger | Yes | Yes |
FFT onboard | No | Yes |
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits | Yes | Yes |
Function | 8558A uX/X of reading + uX/X of range | 8588A uX/X of reading + uX/X of range | ||||
---|---|---|---|---|---|---|
95% | 99% | 95% | 99% | |||
DC voltage | 10 V | relative | 4.0 + 0.06 | 5.2 + 0.08 | 2.7 + 0.05 | 3.5 + 0.06 |
absolute | 4.1 + 0.06 | 5.3 + 0.08 | 2.8 + 0.05 | 3.6 + 0.06 | ||
AC voltage | 10 V, 1 kHz | relative | 80 + 10 | 103 + 13 | 60 + 5 | 77 + 6.5 |
absolute | 90 + 10 | 116 + 13 | 64 + 5 | 83 + 6.5 | ||
Resistance | 10 kΩ | relative | 10 + 0.6 | 13 + 0.7 | 7 + 0.5 | 9 + 0.6 |
absolute | 10.3 + 0.6 | 13.3 + 0.7 | 7.2 + 0.5 | 9.2 + 0.6 | ||
DC current | 1 mA | relative | 9 + 5 | 12 + 6 | 6.5 + 4 | 8.4 + 5 |
absolute | 9.8 + 5 | 13 + 6 | 7.6 + 4 | 10 + 5 | ||
AC current | 1 mA, 1 kHz | relative | 300 + 100 | 387 + 129 | 250 + 50 | 323 + 65 |
absolute | 310 + 100 | 400 + 129 | 260 + 50 | 335 + 65 | ||
Frequency | 1 kHz | relative | N/A | N/A | 0.5 | 0.5 |
Temperature | PRT 100 Ω | relative | ± 5 mK | ± 5 mK | ± 5 mK | ± 5 mK |
Capacitance | 1 uF | relative | N/A | N/A | 400 + 100 | 516 + 129 |
absolute | N/A | N/A | 406 + 100 | 523 + 129 |
95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2)
Looking for lower specs? See our other benchtop multimeters:
Bench Multimeter Selection Guide | |||
---|---|---|---|
Model | Resolution | Accuracy | Application |
8588A | 8.5 | 2.7 µV/V 95% confidence level, 1-year relative accuracy | Metrology |
8558A | 8.5 | 4.0 µV/V 95% confidence level, 1-year relative accuracy | High-Speed Automation |
8845A/8846A | 6.5 | Basic V dc accuracy of up to 0.0024 % | Bench |
8808A | 5.5 | Basic V dc accuracy of 0.015 % | Bench |
Accessory | Description |
---|---|
Y8588 | Rack Mount Kit (2U – 3.5 in) |
Y8588S | Slide Rack Mount Kit |
8588A-LEAD | Comprehensive Measurement Lead Kit Includes:
|
8588A-SHORT | 4-Way Shorting PCB |
8588A-LEAD/THERMAL | Low Thermal Lead Kit |
8588A-7000K | Cal Kit with 1 Gohm Standard and Connecting Leads |
96000SNS | Additional Power Sensor |
8588A/CASE | Transit Case |